If someone in your home uses a wheelchair, or you’re planning ahead for later life, door widths quickly become one of the most important details in the house. A doorway that’s a few centimetres too narrow can mean scraped knuckles, damaged frames or a room that simply can’t be reached.
This guide explains what the official guidance in England says about door widths, how to measure the width that actually matters, and the practical options for making doorways more accessible, from choosing a wider standard door to fitting a made-to-measure door or a pocket door.
The measurement that matters: clear opening width
When people talk about door width, they usually mean the size of the door leaf. For wheelchair access, the figure that counts is the clear opening width.
Approved Document M, the government guidance on access to and use of buildings, defines this as the clear distance between the inside face of the door frame (or door stop) and the face of the door when it’s open at 90 degrees. Handles and other door furniture can be ignored when you measure it.
In practice, the clear opening is always narrower than the door leaf, because the door stop and the thickness of the open door both take up space. That’s why a door that sounds generous on paper can still be a tight squeeze.
How to measure your clear opening
- Open the door to 90 degrees, so it’s square to the wall.
- Measure from the face of the open door to the door stop on the opposite side of the frame.
- Take the measurement at a few heights, because frames aren’t always perfectly straight.
- Use the smallest figure.
If the door can’t open to a full 90 degrees, the usable width will be even less.
What Approved Document M says
Approved Document M Volume 1 covers dwellings in England. It sets out three categories of home:
- Category 1 (M4(1)): visitable dwellings, the baseline for new homes
- Category 2 (M4(2)): accessible and adaptable dwellings
- Category 3 (M4(3)): wheelchair user dwellings
Categories 2 and 3 are “optional requirements”. They only apply to a new home when the local planning authority makes them a condition of planning permission. Otherwise, new homes only need to meet Category 1.
Category 1 and 2: 750mm to 800mm, depending on the corridor
For visitable and accessible homes, the guidance links the minimum clear opening width to the width of the corridor leading to the door. The tighter the turn into the room, the wider the door needs to be:
| Door clear opening width | Minimum corridor width |
|---|---|
| 750mm or wider | 900mm (when approached head-on) |
| 750mm | 1,200mm (when approach is not head-on) |
| 775mm | 1,050mm (when approach is not head-on) |
| 800mm | 900mm (when approach is not head-on) |
The document also notes that a standard 826mm door leaf up to 44mm thick is deemed to satisfy a requirement for a 775mm clear opening. Category 2 homes also need a minimum 300mm “nib” (a short stretch of wall) beside the leading edge of doors on the entrance storey, so there’s room to reach the handle from a wheelchair.
Category 3: 850mm clear opening
Wheelchair user dwellings go further. Every internal door should have a minimum clear opening width of 850mm, whichever direction you approach it from. Hallways and landings should be at least 1,050mm wide, rising to 1,200mm where the approach to a door isn’t head-on. There should be a 300mm nib to the leading edge and a 200mm nib to the following edge of every door.
The Category 3 guidance also says door handles, locks, latches and catches should be easy to grip and use, and fitted 850mm to 1,000mm above floor level.
Does this apply to my existing home?
Approved Document M Volume 1 applies to newly built dwellings and to homes undergoing material alteration, where the work shouldn’t leave the home less compliant with Category 1 than before. It doesn’t apply to extensions. So if you’re simply replacing doors in an existing house, these figures aren’t a legal requirement, but they’re the best available benchmark for what works. If you’re adapting a home for a specific person, an occupational therapist can advise on the widths their wheelchair and way of moving actually need.
What width should I aim for?
As a rule of thumb:
- 800mm clear is a sensible target for most doors in a home where a wheelchair is used occasionally, especially off narrower hallways.
- 850mm clear is the Category 3 figure and the safer choice for a full-time wheelchair user, larger powered chairs, or anywhere the approach involves a turn.
- Wider still can help in tight spots, for anyone who needs help from a carer walking alongside, or for a bedroom where a hoist or bed may need to pass through.
Measure the wheelchair too. Chair widths vary, and hands on the push rims add width.
Will a standard UK door be wide enough?
UK internal doors are mostly sold in imperial sizes, such as 762mm (2ft 6in) and 838mm (2ft 9in) wide, or metric sizes such as 826mm and 926mm. Many older homes have 686mm or 762mm doors, which won’t give anything close to an accessible clear width.
Upgrading to the widest standard door your opening can take is the simplest improvement. Remember the clear opening will be smaller than the leaf, so check the figures before you order. Our door sizes reference guide lists the common UK sizes.
Options for widening a doorway
Fit a wider door in a widened opening
In a stud wall, widening an opening is usually a manageable building job. In a load-bearing or masonry wall, you’ll need a suitable lintel and may need building regulations approval, so get advice from a builder or structural engineer first. Once the opening is enlarged, a new lining and a wider door can go in.
Choose a made-to-measure door
If the ideal width falls between standard sizes, or your opening is an odd size, a made-to-measure door means you can use every available millimetre. That can make the difference between 780mm and 850mm of clear width. Our made to measure service can supply bespoke-sized doors and complete door sets, and our guide to non-standard door sizes explains when bespoke is worth it.
Consider a pocket door
A pocket door slides into the wall, so there’s no swing to manoeuvre around and no door leaf to pull towards you from a seated position. Most systems are top-hung with only a small floor guide, so the floor stays level through the opening.
Pocket doors do have trade-offs. The handle is a flush pull, which some people find harder to grip, and the leaf often stops slightly short of fully disappearing so the pull can be reached, which reduces the clear opening a little. Check the passage width in the kit maker’s table rather than assuming the leaf size is the opening. Our pocket door sizes guide explains how, and our automatic pocket doors guide covers motorised options. You can browse kits on our pocket door kits page.
Other details that make doors easier to use
- Level thresholds. Approved Document M describes an accessible threshold as level or, if raised, no more than 15mm high in total, with any upstands over 5mm chamfered.
- Easy-grip handles. Lever handles are generally easier to use than knobs. Fitting them at a consistent, reachable height helps too.
- Lighter doors and gentler closers. Heavy doors with strong closers can be hard to open from a wheelchair. Fire doors need a closer only where the guidance or your fire strategy calls for one, so check before fitting one unnecessarily.
- Space beside the handle. That 300mm nib on the leading edge lets a wheelchair user get close enough to reach the handle without the footplates hitting the door.
- Clear corridors. Avoid radiators or furniture opposite doorways, where they’ll get in the way of turning.
Help with the cost of adaptations
If you or someone you live with is disabled and needs changes to your home, you may be able to get a Disabled Facilities Grant from your local council. GOV.UK lists widening doors among the types of work it can cover.
Frequently asked questions
What is the minimum door width for wheelchair access in the UK?
For new homes in England, Approved Document M gives minimum clear opening widths of 750mm to 800mm for Category 1 and 2 homes, depending on the corridor width, and 850mm for Category 3 wheelchair user homes. These are clear opening widths, not door leaf sizes.
Is a 762mm (2ft 6in) door wide enough for a wheelchair?
Usually not comfortably. Once the stop and the open door are taken into account, the clear opening will be well under 762mm, which is narrower than the minimum figures in Approved Document M.
What size door gives an 850mm clear opening?
It depends on the frame, the stops and the door thickness, so there isn’t one answer. Measure the clear opening a door set will give, or ask your supplier for the clear width before you order. A made-to-measure door can be sized to hit a specific clear width.
Are pocket doors good for wheelchair users?
They can be, because there’s no door swing and the floor stays level. Choose a wide enough leaf, confirm the passage width with the kit maker, and make sure the pull handle is easy for the user to grip.
Do I need building regulations approval to widen a doorway?
Not always. Widening an opening in a non-load-bearing stud wall is often straightforward, but work to a load-bearing wall needs a correctly sized lintel and may need approval. Check with your local building control body or a qualified builder.
Planning a more accessible home?