FD30 vs FD60 Fire Doors: What’s the Difference and Which Do You Need?

If you’re shopping for fire doors, you’ll quickly see two ratings come up again and again: FD30 and FD60. They look similar, they’re often sold side by side, and they can even share the same panel design. But they’re not interchangeable, and choosing the wrong one can mean either failing a building control inspection or paying for a heavier door you didn’t need.

This guide explains what the two ratings actually mean, how FD30 and FD60 doors differ in practice, where each one is normally used, and the questions to ask before you order.

What do FD30 and FD60 mean?

The “FD” rating is the traditional British way of describing a fire door. It comes from the furnace test in BS 476-22, and the number is the time in minutes that the complete doorset kept its integrity, in other words how long it stopped flames and hot gases getting through.

  • FD30 means the doorset held back fire for 30 minutes in the test.
  • FD60 means the doorset held back fire for 60 minutes.

You’ll often see an “S” added, as in FD30S or FD60S. That means the doorset also restricts the leakage of cold smoke, which is usually achieved with smoke seals around the frame or door edges.

The European equivalents

Doors tested to the European method (BS EN 1634-1) are classified under BS EN 13501-2 instead. The nearest equivalents are:

British ratingNearest European class
FD30E30
FD30SE30 Sa
FD60E60
FD60SE60 Sa

The “E” stands for integrity. Be careful not to confuse these with EI30 or EI60, which add an insulation requirement that most fire doors aren’t designed to meet. Approved Document B also makes the point that national and European classifications don’t automatically equate, so a door can only claim a European class if it has been tested for it.

A change to keep in mind

Approved Document B (England) currently accepts either the British or the European route. Amendments to the guidance are set to remove the BS 476 fire resistance references from 2 September 2029, subject to transitional provisions. For most homeowners buying a door today this doesn’t change anything, but it’s worth knowing if you’re planning a long project or specifying doors for a developer.

How FD30 and FD60 doors differ in practice

Thickness and weight

The most obvious difference is size. Most timber FD30 doors are 44mm thick. FD60 doors are thicker. For example, our LPD Vancouver 5P White Primed FD60 Fire Door is 54mm thick. The extra thickness and denser core make FD60 doors noticeably heavier, which affects the hinges, the frame and how easy the door is to handle.

Frames and linings

Because the leaf is thicker, an FD60 door needs a frame or lining with a deep enough rebate or stop to suit it. An FD30 lining won’t simply take an FD60 leaf. The frame, seals and hardware all need to match what was tested with the door, so plan the whole doorset rather than just the leaf.

Seals, hinges and hardware

Both types rely on intumescent seals that swell in a fire to close the gap between the door and the frame. The type, size and number of seals depend on the door’s test evidence, and an FD60 door may need a different specification from an FD30. Hinges, locks, latches and closers should be suitable for the rating and the weight of the door. If you’re fitting hinges yourself, our guide on how to install fire door hinges explains what to look for.

Cost

FD60 doors usually cost more than an equivalent FD30, and the matching frame, seals and ironmongery can add to that. That’s one reason not to over-specify: an FD60 door in a place that only needs FD30 adds cost and weight without a compliance benefit.

Where FD30 doors are used

For most homes, FD30 is the rating you’ll come across. Approved Document B’s table of fire door provisions lists FD30S (E30 Sa) for a number of common situations, including:

  • the door between a house and an integral garage
  • flat entrance doors onto a common corridor or stairway
  • doors enclosing protected stairways in flats and many other residential buildings

In a typical house, many internal doors onto an escape route only need to meet FD20 (E20), but FD30 doors are widely used because they’re easy to buy and give a little extra margin. Our guide to FD30 door requirements explains when fire doors are needed in a house, including three-storey homes and loft conversions.

Where FD60 doors are used

FD60 doors are much less common in ordinary homes. They tend to appear where the wall around them needs a higher level of fire resistance, for example:

  • in a compartment wall that separates one building from another, where Approved Document B asks for at least 60 minutes
  • in commercial, mixed-use and some larger residential buildings, where the fire strategy calls for 60-minute compartments
  • where a building control officer or fire engineer has specified 60 minutes for a particular opening

The key point is that the required rating comes from the building’s fire strategy and the wall the door sits in, not from personal preference. A door in a 60-minute wall usually needs a 60-minute rating, while a door in a 30-minute wall normally only needs FD30.

Can you fit an FD60 door where FD30 is required?

In principle, a higher-rated door can meet a lower requirement, provided the complete doorset (door, frame, seals and hardware) is installed in line with its own test evidence. In practice it’s rarely the best choice for a home: the door is heavier, the frame has to suit the thicker leaf, and the overall cost is higher. If you want a sturdier door for sound or security reasons, talk to us first so we can check whether a better-specified FD30 door would do the job.

The reverse is never acceptable. An FD30 door can’t be used where FD60 is required, however well it’s fitted.

What makes either door work: installation matters

A fire door’s rating applies to the tested doorset, so a top-quality door can be let down by poor fitting. Whichever rating you choose:

  • Keep the gaps right. Gaps between the door and frame are often between 2mm and 4mm, but always follow the manufacturer’s figures.
  • Use the right seals. Intumescent and smoke seals should be the type specified for that door and fitted full length.
  • Don’t modify the door beyond its limits. Trimming, cutting in glazing or fitting non-approved hardware can invalidate the certification. If you want glass, choose a factory-glazed door such as those in our glazed fire doors range.
  • Keep the label. The certification label or plug shows what the door is. Don’t remove it or paint over it.

Our guide on how to check a fire door walks through the checks to make once it’s fitted.

Pocket and concealed fire doors

If you’d like a sliding or flush-to-wall look, fire-rated options exist, but the whole system has to be tested together. Our guides to FD30 pocket doors and FD30 concealed doors explain what’s involved.

Frequently asked questions

Is an FD60 door better than an FD30 door?

It offers longer fire resistance in the test, but “better” depends on where it’s going. If the location only requires FD30, an FD60 door adds weight and cost without helping you comply. Choose the rating the building needs.

Do I need FD60 doors in my house?

Most houses don’t. Common domestic locations, such as the door to an integral garage, call for FD30S under Approved Document B. FD60 is more usual in commercial buildings or where the fire strategy asks for 60-minute compartment walls. Check with building control if you’re unsure.

How thick is an FD60 fire door?

It varies by manufacturer, but FD60 doors are thicker than FD30 doors. The FD60 doors in our range, such as the LPD Vancouver 5P, are 54mm thick, compared with the 44mm that’s typical for timber FD30 doors.

Can I use an FD30 frame with an FD60 door?

Not usually. The frame, seals and hardware should all match the door’s test evidence, and a thicker FD60 leaf needs a frame designed to suit it. Check the manufacturer’s installation instructions before ordering.

What does the S mean in FD30S or FD60S?

The S means the doorset also restricts cold smoke leakage, normally with smoke seals. Some locations, such as the door between a house and an integral garage, call for the S rating.

Find the right fire door for your project

Browse our full range of fire doors, including FD30 and FD60 options, or contact our team if you’d like help choosing the right rating, frame and hardware.

Leave a Reply

Your email address will not be published. Required fields are marked *