The gap under an internal door is easy to ignore until something goes wrong. Too small, and the door scuffs the carpet or the bathroom fan struggles. Too big, and you get draughts and noise, or a fire door that no longer does its job.
This guide explains what a door undercut is, what the official guidance in England says, how to measure it properly and how the rules change for fire doors, pocket doors and concealed doors.
What is a door undercut?
A door undercut is the gap between the bottom edge of a door and the floor finish beneath it. On site, “undercutting” also means trimming the bottom of a door to create or enlarge that gap, usually after new flooring has gone down.
The gap does three jobs:
- Clearance. The door has to open and close without catching on the floor, rugs or thresholds.
- Air movement. Air needs to pass between rooms so that extract fans and the home’s ventilation system can work.
- Allowance for the floor. Floors are rarely perfectly flat across the whole arc of a door swing.
What Approved Document F says
In England, the guidance on ventilation sits in Approved Document F, Volume 1 (Dwellings), 2021 edition. It says internal doors should allow air to flow through the dwelling by providing a minimum free area equivalent to a 10mm undercut in a 760mm wide door. In practice, that means:
- If the floor finish is fitted: undercut the door to 10mm above the floor finish.
- If the floor finish isn’t fitted yet: undercut to 20mm above the floor surface, to leave room for the finish.
The same guidance appears in the section on work to existing homes, for example when a new wet room such as a bathroom or WC is added. A new 2026 edition of Approved Document F takes effect from 24 March 2027 for most building work, and it keeps the same undercut wording.
Wales, Scotland and Northern Ireland have their own building regulations, so check the local guidance if your project is outside England.
Why the figure is an area, not just a height
The guidance is really about free area. A 10mm gap under a 760mm door is about 7,600mm². The BWF Fire Door Alliance points out that this works out at 10mm for a 762mm wide door, reducing to about 8mm for a 926mm wide door, because the wider door has more length for air to pass under.
If you’re working to a precise ventilation design, follow the figures your designer or building control body gives you.
Why the gap under the door matters
Modern homes are more airtight than older ones, so air has to be able to move from room to room on purpose. When a bathroom, WC or kitchen fan is running, it pulls air out of that room. Replacement air has to come from somewhere, and the gap under the door is the usual route.
If the door is tight to a thick new carpet, the fan can’t move air as it should. That can leave steam and smells hanging about and, over time, contribute to condensation.
There’s also a sound trade-off. The gap under a door is one of the main ways sound gets past it. Our guide to concealed door soundproofing explains how to balance quiet rooms with the need for air movement.
How to measure a door undercut
Always measure from the finished floor surface, not the subfloor or screed. That’s the top of the carpet pile, the tile or the floorboard, whatever the door will actually pass over.
- Know the final floor build-up. If flooring isn’t down yet, add up underlay, boards, tiles, adhesive and any underfloor heating. Our guide to pocket door flooring explains finished floor level in more detail, and the same principle applies to hinged doors.
- Check the whole swing. Open the door slowly and look for the highest point in its arc. A floor that rises towards the hinge side can catch a door that clears the threshold.
- Allow for rugs and mats. A rug that sits inside the door swing effectively raises the floor.
- Measure at both ends of the door. An uneven gap can point to a sloping floor, a dropped door or worn hinges.
How to undercut an existing door
If new flooring has made a door too tight, the bottom usually needs trimming. Before you cut:
- Check how much you can take off. Many doors have limits on trimming, especially hollow-core and engineered doors with a narrow timber edge. Your door’s instructions or the manufacturer will tell you.
- Mark the line with the door hung. Measure up from the new floor at both ends of the door and transfer the line once the door is off.
- Use a sharp saw or plane and score the line first to reduce splintering on veneered or painted faces.
- Seal the cut edge. Manufacturers often ask for trimmed edges to be sealed. LPD’s finishing guidelines, for example, say trimmed door edges need finishing with a polyurethane varnish.
Fire doors and undercuts
Fire doors are where you need the most care, because the gap under the door forms part of how the door was tested and certified.
The BWF Fire Door Alliance says the gap at the bottom of a fire door is usually around 8mm to 10mm where the door provides fire resistance only, but you must check the door manufacturer’s installation instructions and data sheet. Where the door also has to control smoke (an FD30S door), the gap should be reduced to 3mm, following BS 8214, unless a smoke seal is used to close the gap.
That can clash with the ventilation guidance. The BWF notes that the maximum under-door gap allowed by a fire door’s test evidence may be less than 10mm. If you need a fire door and a ventilation route in the same doorway, talk to your building control body or designer before you trim anything, rather than simply cutting the door to suit.
A few other points:
- Don’t trim beyond the permitted limits. Our guide on whether you can cut a fire door covers what’s allowed.
- Watch the gap over time. Doors drop and floors change. Our 5-step fire door check includes the gaps.
- Know which doors need to be fire doors. Our guide to FD30 door requirements explains where they’re expected in homes, such as the door to an integral garage.
Pocket doors and undercuts
A pocket door slides on a top track, so the gap at the bottom is about clearance, not swing. Most kits include a floor guide that runs in a groove in the bottom of the door, and the hangers usually allow some height adjustment to set an even gap.
The exact clearance depends on the kit, so follow the instructions supplied with it. Plan the finished floor level before the frame goes in, because the hanger adjustment is meant for fine-tuning, not for making up a big change in floor height. You’ll find kits and spares in our pocket door kits range.
Concealed and flush to wall doors
Concealed doors are usually made to order and set from the finished floor, so the undercut needs to be agreed before the door is made. Some concealed door sets list a ventilation undercut as an option. Our Bespoke Concealed Door Set, for example, offers ventilation sleeves and a ventilation undercut as extras.
When you order, have your finished floor level confirmed and tell your supplier which rooms need the ventilation gap. Our guide on how to measure for a concealed door walks through the measurements, and you can browse the range of concealed doors.
Common undercut mistakes
- Measuring from the screed and then losing the gap when the floor goes down.
- Fitting thick carpet after the doors without rechecking every door.
- Trimming a fire door “a bit more” to clear a rug, and ending up outside its certified gap.
- Fitting a brush or drop seal everywhere for sound or draughts, then wondering why the bathroom fan can’t clear the steam.
Frequently asked questions
How much gap should there be under an internal door?
In England, Approved Document F says internal doors should provide a free area equivalent to a 10mm undercut in a 760mm wide door. That usually means 10mm above the fitted floor finish, or 20mm above the floor surface if the finish isn’t down yet.
Do all internal doors need an undercut?
The guidance in Approved Document F applies to internal doors in new homes and to certain work in existing homes, such as adding a new wet room. In any home, a sensible gap helps fans and ventilation work properly.
Can a fire door have a 10mm gap underneath?
Sometimes. The BWF says the gap is usually around 8mm to 10mm for fire resistance only, but it must follow the door’s certification. Smoke-control doors need a 3mm gap unless a suitable smoke seal closes it.
Should I measure the undercut from the floorboards or the carpet?
From the finished surface the door passes over, which means the top of the carpet if that’s what’s fitted.
Can I fit a draught excluder to a door that needs an undercut?
A seal that closes the gap also blocks the air path. If the door needs a ventilation route, speak to your designer or building control body about another way to provide the same free area first.
Get the gap right first time
A few millimetres under a door makes a real difference to how a home feels and how safely it performs. If you’re planning new doors, browse our fire doors, concealed doors and pocket door kits, and get in touch if you’d like help choosing the right door for each room.