Shopping Cart

Fire Door Ironmongery: Hinges, Locks, Handles and Closers Explained

A fire door is only as good as the parts fitted to it. You can buy a properly certified FD30 door, then undo much of its performance with the wrong hinges, a cheap plastic handle or a lock fitted without its intumescent protection.

This guide explains which items of ironmongery (door hardware) matter on a fire door, the standards to look for, and what is and isn’t needed inside a typical home.

Why ironmongery matters on a fire door

A fire door is tested as a complete assembly: the leaf, the frame, the seals and the hardware together. The Guild of Architectural Ironmongers (GAI) says fire doors must be installed to replicate their tested condition, and that changing them in any way is likely to harm their fire performance and nullify any third-party certification or CE/UKCA mark.

Hardware is often where things go wrong. The DHF and GAI Code of Practice: Hardware for Fire and Escape Doors warns that holes are too often drilled through timber fire doors and large metal components attached “with no thought as to the consequences”.

The golden rule: check every item against the door’s certificate, data sheet or field of application report before you fit it. If the paperwork doesn’t cover it, ask the door manufacturer or supplier.

Essential vs non-essential hardware

The GAI splits fire door hardware into two groups.

Essential hardware is critical to the door doing its job. Depending on the door, it can include:

  • Hinges (or pivots) to hang the door
  • A door closer, where one is needed
  • A lock or latch
  • Lever or pull handles to open it
  • Intumescent seals, sometimes with a smoke seal
  • Signage, where required

The GAI says hinges, closers and locks or latches must be CE/UKCA marked on new-build work, and that all items must have proven fire performance to be used on a fire door.

Non-essential hardware includes items such as kick plates, letter plates and door viewers. They don’t help the door resist fire, but the Code of Practice says they must in no way reduce its ability to do so.

Fire door hinges

What to look for

  • CE or UKCA marking to BS EN 1935, the standard for single-axis hinges. The GAI says hinges on fire doors must carry this marking.
  • Fire test evidence. The Code of Practice says the hinge must have been included in a satisfactory fire test on a door assembly of the type it’s going on.
  • A suitable grade. BS EN 1935 grades hinges by door weight and durability. Grade 13 hinges, for example, are commonly specified for fire doors; hinge maker Union describes its fire-rated grade 13 hinge as tested to 200,000 cycles and suitable for doors up to 120kg.
  • A high melting point. Approved Document B says the essential parts of fire door hinges should be made of non-combustible material with a melting point of at least 800°C, unless shown to be satisfactory as part of a tested fire doorset.

How many hinges?

The Code of Practice says it’s usual for at least three hinges to be fitted on fire doors, and that it’s unsafe to alter the “as tested” hinge positions without assessment from a suitably qualified authority. Always follow the positions on your door’s data sheet.

Many fire-rated hinges are also fitted with intumescent pads behind the leaves. Union, for example, supplies intumescent plates with its fire-rated hinge and says an intumescent is essential for fire door use. Our older guide on how to install fire door hinges covers fitting in more detail.

Locks and latches

  • Look for CE/UKCA marking to BS EN 12209, the standard for mechanical locks and latches. The GAI says locks on fire doors must carry it.
  • Fit the intumescent protection. Mortice locks and latches remove timber from the door edge, which is a weak point in a fire. The GAI’s guidance says intumescent protection must match the fire test or certification evidence in type, quantity and thickness. If your lock came with intumescent sleeves or pads, use them; don’t swap in a generic alternative.
  • Check the strike plate. The GAI’s checklist includes making sure latches close easily and bolts line up with the keep.

Handles and pull handles

The Code of Practice says lever handles and knobs should comply with BS EN 1906, and pull handles with BS 8424, with evidence from an approved third-party body. It also says door furniture should have been included in a satisfactory fire test on a similar type of door.

Two practical points stand out:

  • Avoid all-plastic levers. The Code of Practice says plastic or polyamide levers should always have a steel core if used on fire doors, because their low melting point could leave the lever inoperable, or let it fall off, before people have escaped.
  • Remove as little wood as possible. It recommends removing the absolute minimum amount of wood from timber fire doors when fitting furniture, and says intumescent sleeves around fixing holes may be required for pull handles.

Door closers

Do fire doors at home need closers?

Usually not inside the house. Approved Document B (Appendix C) says fire doorsets within flats and dwellinghouses don’t need self-closing devices. It does say they’re needed on flat entrance doors and on the door between a house and an integral garage. Our guide to FD30 door requirements explains where fire doors are typically needed in a house.

Choosing a closer

Where a closer is needed, the Code of Practice says it should be CE/UKCA marked to BS EN 1154. That standard says closers below power size 3 aren’t suitable for fire doors, because their closing force is too low. The closer must close the door fully from any angle, overcoming the latch and seals.

Rising butt hinges are sometimes used as a simple closer. The Code of Practice notes they are still permitted within dwellings and flats for certain domestic applications, but doesn’t recommend them for self-closing fire doors because their closing action is very low.

For flush and hidden doors, our concealed door closers guide compares overhead, concealed and hinge-based options.

Holding a fire door open: what’s allowed

Wedges, hooks and other manual hold-opens are a common problem. The Code of Practice says manually operated mechanical hold-open devices should not be used on fire-resisting doors, because they stop the door closing.

If a self-closing fire door needs to stand open, the safe route is a hold-open or free-swing device linked to a fire alarm. The Code of Practice says these should comply with BS EN 1155 and release the door when the alarm sounds or the power fails.

Seals, kick plates, letter plates and viewers

  • Intumescent and smoke seals. These expand in heat to close the gap between door and frame. The GAI quotes a Fire Door Inspection Scheme survey in which 61% of doors inspected had intumescent or smoke seals missing or faulty, and 34% had excessive gaps. Our guide on how to check a fire door shows what to look for.
  • Kick and protection plates. The Code of Practice says these are generally acceptable when surface mounted, no thicker than 2mm, not wrapped around the door edge and within size limits, but the door’s field of application always takes priority.
  • Letter plates. Only fit a fire-tested letter plate, with its own intumescent, to a door tested to accept one.
  • Door viewers. The Code of Practice says these shouldn’t be fitted to fire doors unless the specific viewer has fire performance evidence for that type of door.

Fire door signs: does your home need them?

Approved Document B says fire doors should generally be marked “Fire door keep shut”, “Fire door keep locked shut” or “Automatic fire door keep clear”, as appropriate. But it exempts doors to and within flats and dwellinghouses, along with a couple of other cases. So the FD30 door to your kitchen or loft room doesn’t need a sign. Communal fire doors in a block of flats are a different matter.

A simple ironmongery checklist

Before you fit anything to a fire door, check:

  1. Is it listed on, or compatible with, the door’s certification?
  2. Is essential hardware CE/UKCA marked to the right standard (BS EN 1935 hinges, BS EN 12209 locks, BS EN 1154 closers)?
  3. Does it come with the right intumescent protection, and are you using that exact product?
  4. Are you keeping to the tested hinge and lock positions?
  5. Will the door still close fully onto its latch and seals?
  6. Have you avoided extra holes, wedges and untested add-ons?

If you’re also cutting or decorating the door, read our guides on whether you can cut a fire door and whether you can paint a fire door first.

Frequently asked questions

What ironmongery does a fire door need?

At minimum, hinges and usually a latch, plus handles to open it and intumescent seals. A closer is needed in some locations, such as the door from a house to an integral garage, but not on most doors inside a house. Everything should match the door’s certification.

Can I use any hinges on a fire door?

No. The GAI says fire door hinges must be CE/UKCA marked to BS EN 1935, and they should be covered by fire test evidence for that type of door. Most fire doors use at least three hinges in their tested positions.

Do fire door locks need intumescent?

Usually, yes. Mortice locks and latches should be fitted with the intumescent protection specified in the door or hardware certification, in the same type, quantity and thickness.

Is it OK to wedge a fire door open?

No. The Code of Practice says manual hold-open devices shouldn’t be used on fire-resisting doors. Use an alarm-linked hold-open device to BS EN 1155 where a self-closing door needs to stand open.

Find the right fire door for your project