Shopping Cart

Can You Fit a Fire Door in an Existing Frame? What to Check First

It’s one of the most common questions we get about fire doors. You need an FD30 door, perhaps for a loft conversion or the door to an integral garage, and the old frame looks perfectly sound. Can you just hang the new fire door in it?

Sometimes, yes. But it’s not as simple as swapping one door for another. A fire door only performs as tested when the frame, seals, hinges and fixings all match its certification. This guide explains what the frame has to match, the checks to make, and when it’s simpler to fit a new fire-rated lining.

The short answer

You can hang a fire door in an existing frame, but only if that frame matches the specification on the door leaf’s data sheet or certificate, and is in good condition and properly fixed and sealed to the wall.

The BWF Fire Door Alliance, the British Woodworking Federation’s fire door scheme, puts it plainly: fitting new fire doors into existing frames is risky, because the existing frame may not be fit for purpose or compatible with the certification of the new door leaf. If it isn’t compatible, the certification becomes invalid.

In practice, many homeowners find it’s easier and more reliable to fit a new fire-rated lining at the same time as the door.

Why the frame matters

A fire door is more than a door leaf. The BWF says the frame, hinges, ironmongery, seals and any glass must all be selected from the installation instructions so that the whole assembly is fire resistant and the parts work together.

It also says the practice of making up a frame on site, hanging a door in it and believing the result is a valid fire door installation “has never been correct”. In a fire, the frame has to hold the door in place, keep the gap around it tight and give the intumescent seals something to expand against. A frame that’s too thin, too soft or badly fixed can let fire round the edges of an otherwise good door.

If you’re not sure whether you need a fire door at all, our guide to FD30 door requirements explains where they’re typically needed in a house.

What the existing frame must match

The BWF’s fact card on fire door frames lists what to check against the door leaf’s data sheet:

  • The material. For example softwood, hardwood or MDF.
  • The density and moisture content of that material.
  • The overall size and profile of the frame or lining.
  • The size and profile of the door stop.

The certification body Certifire, in guidance published by the BWF, gives a general rule of thumb: softwood is acceptable for FD30 doors, hardwood is acceptable for FD60 doors (though some species may not be used), and MDF frames aren’t always allowed, so they must be checked against the door’s certification. It also says your frame must be greater than the minimum section size and density shown in the door’s instructions.

What about the door stop?

You’ll often hear that fire door stops must be 25mm deep. That’s not quite right. ASDMA, the Architectural and Specialist Door Manufacturers Association, says the stop size depends on the detail the door manufacturer has tested or had assessed, and that it is not necessary for a doorstop to be 25mm deep. Follow the stop size given for your door.

Stops can be cut into the solid frame as a rebate or “planted” on as a separate strip. The BWF says a planted stop should be fixed as described in the door’s field of application report.

The other checks before you reuse a frame

Matching the specification is only half the job. The BWF also says to check:

  • The fire stopping behind the architrave. The gap between the frame and the wall needs suitable fire stopping. This is particularly important when the old door wasn’t a fire door, because the frame would have been fitted without fire resistance in mind. The BWF’s installation advice says voids between the frame and wall should be tightly packed with mineral wool. BS 8214:2016, the code of practice for timber-based fire door assemblies, gives guidance on suitable materials.
  • Old hardware recesses. Material removed from the frame for previous hinges, latches or locks mustn’t affect the certification of the new door or its ironmongery. Old hinge and keep recesses in the wrong place are a common problem.
  • The wall itself. The BWF says fire door frames should be fitted into walls with at least the same proven fire resistance as the finished door assembly.

Safelincs, a fire safety supplier, adds that damage, gaps at joints, missing hardware or misalignment between frame and wall, or frame and door, may make an existing frame unsuitable.

Does the door fit the frame?

Most FD30 timber doors are 44mm thick. Many ordinary internal doors are 35mm, so an old frame’s stops may be set for a thinner door. A thicker door also changes the hinge positions and recesses. And if you’re moving up to FD60, our 54mm FD60 doors are thicker again. Our guide to FD30 vs FD60 fire doors explains the difference.

The gaps matter too. The BWF says the gap between the door and frame at the top and sides should generally be 2mm to 4mm, with the threshold gap as per the manufacturer’s instructions. If your old frame is out of square, you may not be able to get an even gap without trimming the door more than its instructions allow. Our guide on whether you can cut a fire door covers trimming limits.

Seals, hinges and ironmongery

Even with a compatible frame, the door needs the right components:

  • Intumescent and smoke seals. The BWF says all fire doors must be fitted with the appropriate seals, either in the frame or in the edge of the door, as stated on the door’s data sheet. An old frame won’t usually have a groove for them.
  • Hinges. Approved Document B says the essential parts of fire door hinges should have a melting point of at least 800°C, unless they’ve been shown to be satisfactory as part of a tested fire doorset. The BWF says essential ironmongery such as hinges, locks and latches must be CE marked, firmly fixed with no missing screws and compatible with the door’s certification.
  • Closers where needed. Approved Document B says fire doors within houses and flats don’t generally need self-closing devices, but some locations do, including the door between a house and an integral garage. Our concealed door closers guide covers the rules.

When to fit a new fire door lining instead

If the old frame fails any of these checks, or you simply can’t confirm what it’s made of, the BWF’s advice points one way: fit a frame or lining that matches the door’s specification.

Safelincs notes that an expert can sometimes inspect an existing frame and give a written assessment, but says the cost is likely to exceed replacing the frame, so it’s usually only practical for large numbers of doors or heritage buildings.

For most homes, a new lining is the simpler route. Our LPD primed white FD30 fire door lining is designed for FD30 internal doors. It comes in 95mm, 108mm, 125mm and 133mm widths to suit different wall thicknesses, is supplied with a loose stop, and has a 20mm x 4mm groove for an intumescent strip. It’s cut to the size of the door on site. A loose stop is useful because it’s fitted after the door is hung, so it can be positioned tight against the closed door.

Always check that the lining is listed as compatible with the door you’ve chosen before you order.

Who should fit it?

The BWF says fire door installation should only be carried out by someone who is competent and specifically trained to install fire doors. Wandsworth Council’s fire door guidance for its leaseholders says new doors fitted to existing frames should always be installed by a certified fire door installer.

If the door is part of building work, such as a loft conversion, building control will also want to see that it meets the regulations. Once it’s in, our guide on how to check a fire door is a useful final check.

FAQs

Can I put a fire door in my old door frame?

Only if the frame matches the material, density, size and stop profile on the door’s data sheet, is in good condition and is properly fire stopped to the wall. If you can’t confirm that, fit a new fire-rated lining.

Does a fire door need a special frame?

It needs a frame that matches the door’s certification. The BWF says frames should conform to the requirements in the door leaf’s field of application and can be bought from the door manufacturer, a licensed frame maker or a distributor.

Do fire door stops have to be 25mm?

Not necessarily. ASDMA says the stop size depends on what the door manufacturer has tested or had assessed. Use the stop size given in your door’s instructions.

Is a softwood frame OK for an FD30 door?

Certifire’s general guidance is that softwood is acceptable for FD30 doors, provided the frame meets the minimum section size and density in the door’s instructions. Always check the specific door’s certification.

What gap should there be around a fire door?

The BWF says it should generally be 2mm to 4mm at the top and sides, with the threshold gap as stated in the manufacturer’s instructions.

Get the door and lining right together

Browse our fire doors, including FD30 and 54mm FD60 options, or contact us and we’ll help you match a door with a compatible lining for your wall.

Leave a Reply