If you let a house in multiple occupation (HMO), fire doors are one of the first things a council officer will look at, and one of the most common sources of confusion. Does every bedroom need an FD30 door? Do they all need closers?
It depends on the type and size of the property. This guide explains how the rules work in England, what national guidance expects for common HMO layouts, and how to keep doors in good order.
It’s a practical summary, not legal advice. Your council’s own HMO standards and your fire risk assessment always take priority.
What counts as an HMO?
GOV.UK describes an HMO as a property rented out by at least three people who are not from one household (for example, a family) but who share facilities such as the bathroom and kitchen. It’s sometimes called a house share.
You must have a licence for a large HMO in England or Wales. That means a property rented to five or more people forming more than one household, where some or all tenants share toilet, bathroom or kitchen facilities, and at least one tenant pays rent. Councils can also require licences for smaller HMOs in their area, so check with yours.
Which rules cover fire doors in an HMO?
There isn’t one single “HMO fire door law”. Instead, several pieces of legislation and guidance work together:
- The Housing Act 2004. Councils use the Housing Health and Safety Rating System (HHSRS) to assess hazards in rented homes, and fire is one of them. Licence conditions can also include fire safety requirements.
- The Management of Houses in Multiple Occupation (England) Regulations 2006. Regulation 4 says the manager must ensure all means of escape from fire are kept free from obstruction and maintained in good order and repair, and that fire alarms and firefighting equipment are kept in good working order.
- The Regulatory Reform (Fire Safety) Order 2005. This applies to the common parts of many HMOs, such as shared hallways and stairs, and requires a fire risk assessment by the “responsible person”.
- LACORS Housing – Fire Safety guidance (2008). This national guidance is widely used by councils and fire services to decide what fire precautions an existing HMO needs, including fire doors.
Wales, Scotland and Northern Ireland have their own rules, so check locally if your property is outside England.
Do all doors in an HMO need to be fire doors?
No. The LACORS guidance sets standards based on risk, using case studies for typical property types. In summary:
| Type of HMO | What LACORS suggests for doors |
|---|---|
| Shared house, up to two storeys | No requirement for fire doors, but sound, well-constructed, close-fitting conventional doors |
| Shared house, three or four storeys | A 30-minute protected escape route with FD30 doors to risk rooms (some relaxation is possible in existing three-storey houses) |
| Shared house, five or six storeys | A 30-minute protected route with FD30S doors |
| Bedsit-type HMO, up to two storeys | A 30-minute protected route with FD30S doors is the preferred option |
| Bedsit-type HMO, three storeys or more | A 30-minute protected route with FD30S doors |
“Risk rooms” are rooms where a fire is likely to start, such as bedrooms, living rooms and kitchens. The guidance focuses on doors from these rooms onto the escape route, which is usually the hallway, landing and stairs leading to the front door.
LACORS also explains that in lower-risk buildings, a full 30-minute protected route need not be insisted on, provided certain conditions are met. One of these is that all risk rooms have sound, close-fitting doors of conventional construction. It warns that lightweight doors and doors with very thin panels should be avoided, and that hollow “egg-box” doors and non-fire-resisting glazed doors should not be accepted.
Your council may set its own standards on top of this, so always read its HMO guidance before you buy doors.
FD30 vs FD30S: what’s the difference?
LACORS explains that FD30 means a doorset with 30 minutes of integrity in a fire test. An “S” after the rating, as in FD30S, means smoke seals are needed to restrict the passage of smoke, including cold smoke.
- Intumescent strips expand when heated, sealing the gap between the door and frame during a fire. LACORS says most timber fire doors will need intumescent seals.
- Smoke seals (usually brush or blade seals) restrict smoke before the intumescent strip reacts.
Smoke seals aren’t always wanted, though. LACORS says that where fire detection is restricted to the escape route, which will often be the case in three-storey shared houses, smoke seals should not be fitted, because the hallway alarm would only sound once the fire was already breaching the door. Where detectors are also fitted inside the rooms, smoke seals are beneficial. So follow your fire risk assessment rather than fitting the highest specification everywhere.
For a deeper look at ratings, see our guides to FD30 door requirements and FD30 vs FD60 fire doors.
Do HMO fire doors need self-closers?
Often, but not always. LACORS says that in most multi-occupancy situations, fire-resisting doors should be fitted with approved self-closing devices. It then sets out where this can be relaxed:
- Entrance doors to flats and bedsit rooms will always require self-closers.
- Doors in low-risk shared houses, and doors within houses or flats occupied by a single household, may be relaxed.
- Doors in larger or higher-risk shared houses and larger flats in multiple occupation may need closers, depending on the overall fire risk assessment.
Where closers are fitted, LACORS says they should comply with BS EN 1154, and that power size 3 will usually be appropriate for FD30 and FD30S doors. In practice, a closer should shut the door fully into its frame and engage the latch. Our fire door ironmongery guide explains closers, hinges and locks in more detail.
Choosing the right fire doors
Buy a certified door and fit it as tested
A fire door is tested as a complete assembly. That means the door leaf, frame, intumescent seals, hinges, lock or latch and closer all need to match the door’s certification. LACORS says fire doors should be installed and maintained in accordance with BS 8214.
When choosing doors:
- Check the door has third-party certification or test evidence for the rating you need.
- Use a matching fire-rated frame or lining, rather than an old, unrated frame. Our guide to fitting a fire door in an existing frame explains why.
- Use fire-rated hinges and locks or latches that match the door’s certification. Some councils’ HMO standards, such as North Tyneside’s, specify three fire-rated hinges.
- Fit intumescent strips and, where specified, smoke seals.
- Don’t trim more than the manufacturer allows. See can you cut a fire door?
You can browse certified doors in our fire doors range, along with matching linings such as our FD30 fire-rated door lining.
Replacing vs upgrading old doors
LACORS says upgrading old, non-fire-resisting doors should be avoided wherever possible, with replacement preferred. Upgrading is mainly for listed buildings or doors worth keeping for their appearance, and must follow a valid test or assessment report exactly.
What about sliding or pocket doors?
A standard pocket door isn’t a fire door and can’t self-close like a hinged door with a closer, so it shouldn’t be used where a fire door is required. Our guide to pocket doors in rental properties explains where they can still work in a let property.
Keeping fire doors compliant
The management regulations require means of escape to be kept in good order and repair, and LACORS expects fire doors never to be propped or wedged open. Build simple checks into your routine inspections:
- Closing: If the door has a closer, does it shut the door fully into the frame and latch from any angle?
- Gaps: Are gaps around the door even, and within the manufacturer’s tolerance?
- Seals: Are intumescent strips and smoke seals present and undamaged?
- Hinges: Are all hinges secure with no missing screws?
- Damage and misuse: Are there holes, added fittings such as extra locks, wedges or disconnected closers?
Record your checks and repairs in a fire safety log book. Our guide on how to check a fire door walks through each step.
Buildings with flats or above 11 metres
If your HMO is part of a building containing two or more sets of domestic premises, such as a converted block of flats, the Fire Safety (England) Regulations 2022 may also apply. GOV.UK guidance says that where the top storey is more than 11 metres above ground, the responsible person must check communal fire doors at least every three months and use best endeavours to check flat entrance doors at least every 12 months. In buildings below 11 metres, the duty under the Fire Safety Order to make sure fire doors provide adequate protection still applies.
Frequently asked questions
Do bedroom doors in an HMO need to be fire doors?
Often. LACORS suggests FD30 or FD30S doors to risk rooms in shared houses of three or more storeys and in bedsit-type HMOs. In a two-storey shared house, sound, close-fitting doors may be enough.
Do HMO fire doors need self-closers?
LACORS says entrance doors to flats and bedsit rooms always need them. In low-risk shared houses, the requirement can be relaxed. In larger or higher-risk properties, it depends on the fire risk assessment.
Should HMO fire doors have smoke seals?
Usually, but not where fire detection is limited to the escape route, as is often the case in three-storey shared houses. Follow your risk assessment.
Can I put a lock on an HMO fire door?
Yes, but the lock must suit the door’s certification and be fitted with the correct intumescent protection. LACORS strongly recommends that the exit door from each bedsit or flat can be opened from the inside without a removable key, for example with a thumb-turn, and says final exit doors in HMOs should always open from the inside without one.
How often should HMO fire doors be checked?
The HMO management regulations don’t set a fixed interval, so your fire risk assessment and licence conditions should set it. Fixed intervals apply in some buildings of flats above 11 metres.
Need fire doors for an HMO?
Explore our fire doors, including FD30 and 54mm FD60 options. If you’d like help matching doors, linings and ironmongery to your council’s requirements, contact our team.