Shopping Cart

Fire Doors in Holiday Lets: What Hosts in England Need to Know

If you let a cottage, flat or spare room to paying guests, fire safety law treats you differently from a homeowner. Guests don’t know the building, may be asleep in an unfamiliar room when a fire starts, and need a safe way out. Doors play a big part in that.

This guide explains what government guidance says about fire doors in holiday lets and other short-term lets in England, which doors matter most, and how to check and upgrade them. It’s general information, not a substitute for your own fire risk assessment.

Which law applies to holiday lets?

In England, the main law is the Regulatory Reform (Fire Safety) Order 2005, usually called the Fire Safety Order. Government guidance says it applies if you charge someone to stay in your property as a guest and the property isn’t being occupied as a private dwelling. Short stays and guests who aren’t friends or family make it more likely the law applies.

That covers holiday cottages, self-catering flats, small B&Bs and rooms let through booking platforms. It doesn’t matter how you advertise the property.

To help small hosts, the government publishes A guide to making your small paying guest accommodation safe from fire. It was first published in March 2023 and last updated in January 2025. It’s aimed at small premises with simple layouts, such as:

  • houses, cottages and chalets on the ground floor, or ground and first floor, sleeping up to 10 people, with no more than four bedrooms on the first floor
  • individual flats, other than unusually large ones

If your property is bigger or has a more complex layout, the guide points you to other government guidance on sleeping accommodation. It also says it doesn’t fit premises whose design differs materially from its examples, such as a two-storey house with an open-plan ground floor, or a flat with a bedroom only reached through another room.

The guide applies only to England. Wales has separate guidance, and Scotland and Northern Ireland have their own fire safety laws.

Your main duty: the fire risk assessment

The person responsible for the premises must carry out a suitable and sufficient fire risk assessment and record the findings. You must keep it under review. The guide says an annual review is usually appropriate, and you should also review it after any significant change or incident.

Doors are one part of that assessment. The checklist in the guide asks whether doors to stairways and escape routes have suitable fire resistance, and whether self-closing devices, where needed, close the doors effectively.

If you don’t feel confident doing the assessment yourself, you can use a competent fire risk assessor. You stay legally responsible either way.

Do holiday lets need fire doors?

Not every door, and not always new certified ones. The aim is to protect the escape route, usually the hallway and stairs, long enough for guests to get out.

Existing solid doors may be acceptable

For the low-risk properties it covers, the guide says it should usually be possible to accept solid, conventional doors that are a good fit in their frames. It describes these as typically a 44mm thick door of solid timber, or one with a flaxboard or chipboard core.

It also says that fitting intumescent strips and smoke seals to existing fire doors isn’t considered essential in these properties. If in doubt, it recommends getting advice from a competent fire safety specialist.

Hollow and glazed doors usually need replacing

The guide is clear that hollow core doors, thin panel doors and plain (non-fire-resisting) glazing in doors or frames give little fire resistance. These will normally need to be replaced with new 30-minute fire-resisting doors.

That catches a lot of holiday properties. Lightweight moulded doors, cottage doors with thin panels and doors with ordinary glass are common, especially after a budget refurbishment. Browse our fire doors if you need FD30 replacements.

Which doors matter in common layouts?

The guide gives example layouts with recommended measures. Here’s what it says about doors.

Two-storey house or cottage

For a three-bedroom, two-storey house:

  • The entrance hall and stairs should be a notional 30-minute protected escape route.
  • Doors opening onto that route should be notional fire doors, but they don’t need to be self-closing.
  • Doors to bathrooms, toilets and cupboards aren’t required to be fire doors.

The guide links to Local Government Association guidance on purpose-built blocks of flats for the definition. In short, a notional fire door is an existing door that met the 30-minute specification or test in force when the building was built or the door was made, rather than one with a modern certificate. The London Fire Brigade notes that older doors like this can still do their job if they’re in good condition, but that a door needing to be fire resisting should be replaced with a proper fire door, not an ordinary one.

Flat with an entrance hall

For a two-bedroom flat in a purpose-built block:

  • The entrance hall should be a notional 30-minute protected route.
  • Doors within the flat should be notional fire doors, with no requirement for self-closers.
  • Doors to bathrooms, toilets and cupboards aren’t required to be fire doors.
  • The flat front entrance door should be a self-closing fire door.
  • Guests should be told to close the doors when sleeping.

Open-plan studio flat

For a studio, the guide focuses on the flat entrance door, which should be a fire door with a self-closing device, and on keeping cooking facilities away from the entrance door so they don’t block the way out.

In a block of flats, the entrance door may belong to the freeholder or be covered by the building’s own fire risk assessment. Check your lease and speak to the managing agent before replacing it.

Keeping doors closed

The guide says keeping doors closed, especially at night, helps stop fire and smoke spreading and gives people more time to escape. It singles out doors to lounges, kitchens and utility rooms used by guests.

Simple steps help:

  • Put a note in your house guide asking guests to close internal doors at night.
  • Don’t leave door wedges in the property. A wedged-open door can’t hold back smoke. Our fire door ironmongery guide explains the safe options if a door with a closer needs to stand open.

Exit doors and locks

The guide says exit doors, such as the front and back door, should always be easy to open from the inside without a key. A simple latch or thumb turn is usually enough, but you may need to think about whether all guests can operate it. A single-action lever handle can be easier.

Fire exit doors should lead to a place of safety clear of the building, without locked gates or fences in the way.

Checking and maintaining your doors

A fire door only works if it’s in good condition. The guide recommends:

  • Every six months: check fire doors are in good condition, undamaged and still a good fit in their frames.
  • Regularly: check that any self-closing devices close the doors properly.
  • Monthly: make sure exit doors not in regular use can be opened easily.

It also recommends keeping a record of testing and maintenance, in a log book or electronically. Between bookings is a good time for a quick look at gaps, damage, hinges and closers.

Our guide on how to check a fire door walks through each point.

Replacing or upgrading doors

If your assessment shows a door needs replacing, a few tips:

  • Buy a proper FD30 door and fit it as the manufacturer intends. The rating depends on the whole assembly, including frame, hinges and gaps. See our guide to FD30 door requirements.
  • Check the frame. Fitting a new fire door into an old frame isn’t always straightforward. Our guide to fitting a fire door in an existing frame explains what to look for.
  • Finish it properly. Most fire doors can be painted, but avoid filling gaps or painting over seals. See can you paint a fire door?

If you also let rooms to long-term tenants, different rules apply. Our guide to fire doors in HMOs covers shared houses.

Frequently asked questions

Do Airbnb properties need fire doors?

If you charge guests to stay and the property isn’t occupied as a private dwelling, the Fire Safety Order applies, whichever platform you use. You must assess the fire risk. In a small house or flat, existing solid, well-fitting doors onto the escape route may be acceptable, but hollow or thin-panel doors usually need replacing with 30-minute fire doors.

Do all doors in a holiday cottage need to be fire doors?

No. In the government’s two-storey house example, doors opening onto the protected hall and stairs should be notional fire doors. Doors to bathrooms, toilets and cupboards aren’t required to be fire doors.

Do holiday let fire doors need self-closers?

In the guide’s house and flat examples, doors inside the property don’t need self-closers. The flat front entrance door should be self-closing. Your fire risk assessment decides what’s needed for your property.

Do I need intumescent strips and smoke seals?

The guide says fitting them to existing fire doors isn’t considered essential in the small properties it covers. New certified fire doors may come with them as part of the tested design, so keep them in place.

How often should I check fire doors in a holiday let?

The guide recommends checking fire doors every six months for damage and fit, and making sure any self-closers work properly. Keep a record of your checks.

Get your holiday let doors right

Solid, well-fitting doors on the escape route, closed at night and checked regularly, go a long way. If your assessment says some need replacing, browse our fire doors or get in touch for help choosing the right FD30 door.

Leave a Reply

Your email address will not be published. Required fields are marked *


Powered by Startup Fast